Non-Contact Phase Detector UNI-T UT262E

id: 910443
id: 910443 0.5 kg Warranty: 24 months
Rate product
The clamp-type non-contact phase detector is designed for phase detection, live wire examination, power inspection, phase loss judgment, finding breakpoints, and positioning breakpoints.
Price coming soon
Contact
sales team
Price coming soon
Contact
sales team
Add to wishlist
Compare
Compare
Impossible to estimate the shipping cost
Overview
Warranty
Overview

UNI-T UT262E is a clamp-type non-contact phase detector. It avoids electric sparks caused by contact with bare wires, thereby reducing the risk of electrical shock for electricians and other professional personnel. The UT262E can also be used for live wire detection, simple electrical inspection, phase identification, missing-phase judgment, wire breaker searching.

It is an excellent tool for phase sequence detection, motor installation, and wire maintenance. It enhances the safety of field testing, ensures the well-being of operators, and improves productivity.

Features

  • Phase-detection
  • Phase missing detection
  • Phase sequence detection
  • Non-contact detection
  • Three-phase AC voltage: 70-1000V AC
  • LED & Buzzer indication
  • Automatic power off

Technical Specifications

Function/Application Phase detection, live wire examination, power inspection, phase loss judgment, breakpoints finding, breakpoints positioning
Measurement method Non-contact
Phase wire position Put the wires at the position between “▲” and “▼” marked on the clamp
Voltage range Three-phase voltage, 70-1000V AC (45Hz ~ 66Hz)
Operating frequency 50 Hz / 60 Hz (±10%) 50 Hz / 60 Hz, automatically identify within the range of frequency error of standard power grid, the frequency range of other variable-frequency power supply is not examined
Test method Non-contact clamping Diameter of wires can be clamped: ø2 mm~ø40 mm
Double-insulated LDPE clamp (0.5 mm²*1C+B), OD: 3.5 mm, extension wire length: 0.6 m
Power supply 1.5V AA × 2 alkaline batteries Continuous working time: more than 20 hours
Power consumption Power-off current is less than 10 uA@3 V Maximum average working current: 70 mA@3 V
Low battery indication <2.4 V The indicator light flashes slowly to indicate low battery
<2 V The buzzer beeps twice to indicate power off
Auto power off After the detector is turned on for about 5 minutes, it will power off automatically and the buzzer will beep twice
Operating temperature 0~50°C (32~122°F)
Operating humidity >85% (Non condensing)
Storage temperature -20~60°C (4~140°F)
Altitude < 2000 m
Button life 10000 cycles
Insulation intensity 3.7kVrms
Buzzing decibel 65~70 dB
IP rating IP52
Safety certification CE, UKCA EN61010-1: 2001, EN61010-031: 2002
Safety rating Pollution Class 2, CAT Ⅳ (600V), CAT III(1000V), 8000V transient overvoltage (only for the clamp)
Product dimension 88 mm × 30 mm × 66 mm
Product weight 237.7 g (with batteries) / 191.5 g (without batteries)

Video

Youtube video

User Manual

PDF  Download UNI-T UT262E user manual.

Package Contents

  • Non-Contact Phase Detector UNI-T UT262E — 1 pc.
  • User Manual — 1 pc.
  • Carrying Bag — 1 pc.
  • AA Alkaline Battery — 2 pcs.
Warranty
Non Contact Phase Detector UNI T UT262E - /*Short description|product*/
ID: 910443
Non-Contact Phase Detector UNI-T UT262E
Price coming soon
Contact
sales team

Customers Feedback

Chat with us
English Offline Español Offline Русский Offline Português Offline
Sales chat
 English offline
 Español offline
 Русский offline
 Português offline
Contacts
Phone:
Email:
Compare
No items in compare list
Sales chat
Contacts
Compare